Virtual Facility for Hyperscale Data Centers

26 June, 2018

In a world where social media is king and Blockchain is the new frontier, cloud applications have begun shaping the next generation of data centers. End users are increasingly looking to the cloud for scalability, infrastructure reliability and faster deployment of applications that can increase productivity.

To meet these new demands, hyperscale owner/operators must eliminate the uncertainty caused by new assets and infrastructural changes. The degree to which you can predict and plan for the impact of these changes determines if you can ensure that critical goals will be met without overspending on design and operations.

How can you see the impact of these potential changes? Our industry-leading Virtual Facility is a digital clone of your data center, and can be used to test design and operational changes. With the ability to design everything from the smallest components in the facility to the data center itself, the VF has the accuracy and power to safeguard your business from the uncertainty of data center performance. Utilizing the same principles of prediction that health, insurance and automotive industries use to mitigate business risk, the VF gives you an insight into future risk that no other tool can match.

Server and Rack Design

To run multiple software applications, IT equipment must be designed with an awareness of both the applications it will run and the data center that will house it. Utilizing a digital prototype of the server, you can design the optimal internal layout, maximizing airflow through the server while keeping the electronics cool at their highest workloads.

The VF’s powerful tools allow you to model IT equipment by importing existing CAD files and utilizing a wide range of intelligent parts, such as components, heat sinks, fans and PCBs. It also allows you to evaluate a wide range of scenarios, such as fan control algorithms, fan failures, and component temperatures during stress conditions. Knowing the true boundary conditions of a piece of IT allows you to address and solve thermal issues during the project’s architectural phase – when changes are easier and less expensive to make.

Figure 1. (Above) Using Computational Fluid Dynamics (CFD), you can design and test a range of server layouts.

Additionally, the servers can be tested in various rack configurations to ensure that any variant of IT stack-up works at different power densities.

Figure 2. (Above) After designing the server in the VF, you can test its performance in a range of rack configurations.

DC Design and Operations

The VF gives you the opportunity to ‘design out’ potential issues before the data center is built. The biggest risks during design are over-engineering and overspending on CapEx (capital expenditure). On the other hand, a poorly designed facility can lead to overspending in OpEx (operational expenditure) when power and cooling infrastructure upgrades become unavoidable.

The variables that affect data center designs are hard to count: from power densities to rack layouts and cooling control systems. With the VF, the entire design can be validated using data from the actual server designed by the hardware team – a critical component in understanding the validity of the design.

Figure 3. Addressing the entire design from server to the data center and beyond

Putting it All Together

Given the seamless transfer of data across the entire platform, you can run various scenarios at the data center level to validate the design at every level. In operations, a key parameter is the constant shifting of power from one section of the data center to another, which can result in hotspots or capacity losses if the control system isn’t tuned appropriately. You can test the impact of varying power load via an external API. Given that the servers used in the model can react to the change in power and external ambient temperature, you can understand where potential hot-spots may occur.

Designing with the End in Mind

Simulating real-world data center components in the VF powered by Computational Fluid Dynamics (CFD) helps you to design with the end in mind: you can evaluate the performance of a server in the rack, and see how that rack will be affected by deployment in the data center. This removes a great deal of risk from the design process.

The VF’s targeted software tools are designed to meet the needs of both server mechanical engineers and data center design engineers, providing a holistic, physics-based solution for every person on your team.


Blog written by: Akhil Docca, Director of Marketing

Other Recent Posts


Managing Energy Consumption for the Surging Data Center Market

Data center operations today are not the same as they were 10 years ago. Between the rapid growth o…

Read More


HF Lenz speeds up design process with 6SigmaRoom and Rescale

Engineering firm uses 6SigmaRoom and Rescale to Deliver Fast and Accurate Results to Demanding Clie…

Read More